1.
Life (Basel) ; 11(11)2021 Oct 22.
Article in English | MEDLINE | ID: covidwho-1480850

ABSTRACT

To combat the COVID-19 pandemic, vaccines against SARS-CoV-2 are now given to protect populations worldwide. The level of neutralizing antibodies following the vaccination will evolve with time and vary between individuals. Immunoassays quantifying immunoglobulins against the viral spike (S) protein in serum/plasma have been developed, but the need for venous blood samples could limit the frequency and scale of control in populations. The use of a quantitative dried blood spot (DBS) that can be self-collected would simplify this monitoring. The objective of this study was to determine whether a quantitative DBS device (Capitainer qDBS 10 µL) could be used in combination with an Elecsys anti-SARS-CoV-2 S immunoassay from Roche to follow the development and persistence of anti-S antibodies. This objective was carried out through two clinical studies. The first study investigated 14 volunteers who received two doses of the Comirnaty (Pfizer) vaccine. The levels of anti-S antibodies and the progression over time post-vaccination were studied for three months. The level of produced antibodies varied between subjects, but a similar trend was observed. The anti-S antibodies were highly stimulated by the second dose (×100) and peaked two weeks later. The antibody levels subsequently decreased and three months later were down to 65%. DBS proved to be sufficiently sensitive for use in evaluating the immune status against SARS-CoV-2 over a prolonged time. The second cohort was composed of 200 random patients from a clinical chemistry department in Stockholm. In this cohort, we had no information on previous COVID-19 infections or vaccination. Nevertheless, 87% of the subjects had anti-S immunoglobulins over 0.8 U/mL, and the bias between plasma and DBS proved to be variable, as was also seen in the first vaccination study.

2.
Bioanalysis ; 13(3): 161-167, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-1067857

ABSTRACT

Aim: Several automated immunoassays have been validated on serum/plasma to evaluate the presence of significant levels of anti-severe acute respiratory syndrome coronavirus 2 (anti-SARS-CoV-2) antibodies, signs of a present or past infection, but the use of dried blood spots (DBS) would facilitate sampling, shipping and storage. Objective: The aim of this project was to give proof of concept of the possibility to use of the automatized Elecsys® anti-SARS-CoV-2 immunoassay with a volumetric DBS device. Results: Linearity and correlation were satisfactory between volumetric DBS and plasma. A cut-off value was suggested and should be validated with more samples. Conclusion: this study strongly support the possibility to work with volumetric DBS instead of serum/plasma to test for anti-SARS-CoV-2 antibodies.


Subject(s)
COVID-19/diagnosis , Immunoassay/methods , Antibodies, Viral/blood , COVID-19/virology , Dried Blood Spot Testing , Humans , Luminescent Measurements , Reagent Kits, Diagnostic , Reproducibility of Results , SARS-CoV-2/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL